Thank You!
|
 |
|

To all our customers and business partners:
Thank you so much for stopping by our booth on Analytica, for your interest and all your support!
We very much enjoyed seeing and talking to you and appreciate all your feedback, input and new ideas!
- We hope to see you again on Analytica 2014 -
|
|
|
|
Free ATR & Raman Spectra
|
 |
|
Download now your free evaluation copy of our ATR-FTIR and Raman spectra!

Click Here To Download
|
|
|
|
 |
Accessories for Spectroscopy
|
 |
|
- Mini Plane Sampling Knife
The Mini Plane is a unique tool to slice or plane surfaces of hard and soft, biological and industrial materials into thin samples for microanalysis.
- KBr-Table Press
Compact designed KBr-Table Press for pellet making for transmission analysis.
- SiCheckIR
The SiCheckIR is an innovative accessory to measure SiH2 composite, organic composites, etc. on Silicone wafers.
Please scroll down to view the details of our accessories for spectroscopic applications.
Should you look for a specific tool, which you do not find on these pages, please get in touch with us for further guidance.
|
|
|
|
Raman SERS Wavelet
|
 |
|
AU Nanorod Array Chips and Plates for Signal Enhancement
Surface Enhanced Raman Scattering (SERS) is a powerful technique for the detection, identification, quantification and structural studies of minute amounts of samples in materials research, surface science, medical diagnostics, biophysics etc.
SERS greatly enhances the Raman signal from sample molecules adsorbed on noble-metal surfaces possessing nano scale roughness.
Intensity enhancements of approx. 104 up to 106 can be obtained routinely on gold surfaces.
Specifications
- Active Surface: Au
- Active Area Chip Dimensions: 5mm x 7mm or 3mm x 4mm
- Plate, External Dimensions: 76mm x 26mm (glass slide)
- Recommended Excitation Wavelength: 633nm, 785nm (recommended), 830nm
Benefits
- Highly reproducible and ultrasensitive measurments with your Raman system
- Ultrasensitive detection and characterization of extremely low concentration of analytes
- Enhancement level sufficient for Raman single molecule detection
- Trace-level analysis and identification of organic and inorganic compounds and contaminants
- Analysis of analytes at low concentration in a liquid or liquid segmented microfluidic system
|
|
|
|
μ Contact Pressure Monitor
|
 |
|
Controls the pressure applied on the ATR crystal during sample analysis
For ATR measurements the pressure is a very significant issue:
Too much pressure and either the sample or the ATR crystal will crack, too little pressure and there is no good contact between the ATR crystal and your sample.
With the μ Contact Pressure Monitor you can set an alarm at a specified pressure.
So while you gradually increase the pressure to obtain a good ATR spectrum, the alarm will be triggered as soon as you reach your pre-specified pressure limit.
Like this you can apply the desired maximum pressure on the sample for obtaining a high quality spectrum without breaking your ATR-crystal.
Features
- Easy handling & mounting
- Universal use with most FTIR –Microscopes
- Can be combined with the MircoVice-Mini for additional ease of use
- Standard 25x27mm back plate of MicroVice-Mini for easy mounting on most microscope
Benefits
- Controlled pressure exertion on sample and ATR-objective
- Acoustic signal prevents applying excessive pressure
- ATR objective and sample are protected efficiently against breaking
- Error measurements resulting from high pressures are eliminated
- Multiple samples can be measured at a specified pressure setting, thus speeding up the processing of sample
|
|
|
|
Diamond EX-Press Compression Cell
|
 |
|
With this compression cell you can easily flatten and thin materials to an ideal thickness for transmission analysis
The sample is simply compressed between the diamond windows by turning thumb screws until the sample is thin enough for the beam of the spectrophotometer to penetrate.
The Diamond Cell simplifies sample preparation of samples, which are difficult to manage by other techniques:
Excellent for analyzing hard materials such as minerals, rubbers, plastics, polymers and also pharmaceuticals. They can be compressed, crushed and flattened to a uniform thickness for IR measurements.
The total cell thickness of 9.5 mm provides smallest working distance for use with microscopes.
- Large clear aperture (1.6 mm or 2.0 mm)
- Universal use with FTIR-Spectrometers & FTIR –Microscopes
- Two type IIa single crystal synthetic diamonds
- Standard 2”x3” back plate fits all spectrometers
- To use without beam condenser
Benefits
- Simplified sample preparation
- Multifunctional use with spectrometer and/or with IR-Microscope
- Minimal interfering absorption bands
- Maximum throughput to the detector without detection saturation
- Easy to assemble and clean
|
|
|
|
Mini Plane - Sampling Knife
|
 |
|
Easily shave off surfaces into thin samples for microanalysis  Proper sample preparation tools are a requirement for any microscopy lab. This is especially true for those performing FT-IR analysis where the sample must be between 5 and 20 microns in order to provide the desired transmission.
The Mini-Plane enables you to shave off the surface of a material such as a polymer and cut a controlled and consistent sized slice of uniform thickness, optimized for measurement.  Features - Adjustable blade depth & cutting angle
- Available with choice of blades: Single Crystal Diamond (cutting width 0,7 mm) or Carbide Steel Blade (cutting width 1,5 mm)
- Ergonomic wooden grip
- Patented design
Benefits - Excellent control and reproducibility of sample thickness
- Precise depth control
- Reduced mechanical damage to specimen
- Allows you to produce sections of various thickness with the same knife
- Easy to clean
|
|
|
|
KRS-5 Wire Grid Polarizer
|
 |
|
Wire grid polarizer for a broad variety of IR reflectance measurements

- Measurement of thin layers or thin films on metal surfaces in Grazing Angle Reflectance mode
- Molecular orientation studies of crystal and polymer films
- Analysis of polymer films, fibers, multilayer coatings, etc.
- Characterization of Langmuir-Blodgett films
Features:
- Wavelength Range: 2.5μm through 25μm
- Polarization Efficiency: >88% (2.5μm), >95% (25μm)
- Extinction Ratios: 2 x 10-2 (2.5μm), 10-2 (3 through 24μm)
- Dimension: 28mm OD x 2mm T
- Clear aperture: 25mm
- Condition in use: Humidity: <60%, Temp.: between 10℃ and 30℃
Benefits
- High transmission
- High extinction
- Number of grooves with aluminum wire: 3200/mm
- Usability in a wide range
- Polarizer comes with double cassette type 360°rotation holder
|
|
|
|
KBr - Table Press
|
 |
|
Compact designed Table Press for KBr-Pellets
This efficient, little KBr Table Press is a valuable addition in any IR Laboratory, which regularly makes KBr pellets.
The smooth action of the handle permits pellets to be pressed effortlessly with one hand and minimal pressure.
Clear KBr pellets with a diameter of 1, 3 and 7mm can easily be pressed.
Features
- Compact design
- Selection of die sets available (1, 3 and 7 mm)
- Components contacting the die set are stainless steel
Benefits
- Sturdy, compact and easy-to-use
- Uniform and highly reproducible pellets
- Easy to clean and maintain
|
|
|
|
Sample Holders for Spectrometers
|
 |
|
The Universal Holder - Versatile All-Round Sample Holder For Transmission Analysis

This universal holder features a spring loaded clip as well as a magnetic plate to hold samples firmly in place.
It can be used for films, pellets, windows, mulls, etc in sample sizes from 13 up to 40 mm diameter and 13 mm thickness.
- The hold down section of the clip is gimballed: It can be flipped over and used facing in either direction providing a 10 mm and a 22 mm aperture
- The 10 mm aperture is removable and can be unscrewed when using the 22 mm aperture
- A thumbscrew provides adjustable pressure on the clip
- A Viton O-ring mounted in the clip protects the sample
- A groove in the base of the holder accommodates two magnets with 10 mm or 22 mm aperture
- Standard sized backplate fits all spectrometers
The Quick Holder - Designed To Hold Collars For 1, 3, 7, And 13mm KBr Pellets

- Magnetic back plate holds the sample in place
- Easy positioning of the sample collar on a removable mount with a half moon cut-out
- Includes 2 interchangeable mounts of different width
- An opening at the top end of the holder is used for 13 mm pellets
- Standard sized backplate fits all spectrometers
- Combines perfectly with our KBr-table press!
The EZ-Clip - Sample Holder With Spring-Loaded Clip

FTIR Transmission Sample Holder for Films
This inexpensive, easy to use holder is designed to hold samples with a spring loaded clip.
It easily holds windows, pellets, and films securely in place.
- A Viton O-ring, mounted in the clip, protects the sample from damage
- Two EZ-Clip models are available
- a 25 mm diameter model - best for windows & films
- a 13 mm diameter model - best for pellets
- Standard sized backplate fits all spectrometers
The K-Holder - Sample Holder For Liquid Samples And Pellets

- Base and positioning mount can be slided up & down (25 mm) in order to position the sample correctly according to its specific size and form
- Includes a mount with a triangular cut-out, which can be fixed on the movable base
- Can be used for IR, UV, NIR, and Raman
- Standard sized backplate fits all spectrometers
Demountable Liquid Cell

The windows that are used in this holder are not amalgamated together, so that the cell is easily convertible to accommodate various window materials and many sampling types.
- Luker-Lok filling ports make filling and clean up easy
- Full flexibility in the selection of window materials and path lengths
- Easily disassembled for cleaning and window replacement
- Cell windows can be assembled with various Teflon spacers sealing and defining the pathlength of the cell
- Standard 2”x3” slide mount
|
|
|
|
SiCheckIR
|
 |
|
ATR-Measurement of Si-Wafers

Si-CheckIR is an accessory to measure SiH2 composites, organic contaminants, etc. on silicone wafers.
For measuring the surface of a silicone wafer a perfect contact between the wafer and the ATR crystal is essential.
- Unique compression mechanism for optimum wafer contact
- The direction of pressure on the Si-wafer is always perpendicular to the ATR-crystal
- The pressure intensity on the entire surface can be adjusted and is always equable and constant
- Ge-crystal
- Reflectance angle 60°
- Precise optics ensure an incident angle of the IR-beam of ±1,5°
- Various sizes for (6”, 8”, and 12”) for measuring larger sized wafers
|
|
|
|
|
In the press
|
 |
|

News zu Laborbedarf, Labortechnik, Laborautomation, Analytik und LifeScience.
|
|
|
|
Contact Us:
|
 |
|
Whether you’re looking for more information, or you have any question concerning our products, please contact us.
We will be happy to assist.
Phone:
+49 (0)2234 956 372
Fax:
+49 (0)2234 956 373
General Inquiries:
mail@stjapan.de
Office Hours:
Monday to Friday
(Except bank holidays)
9 am to 5 pm CET
|
|
|